KEBO 3KVA Uninterruptible Power Supply (UPS) Specifications
This specification sheet outlines the typical electrical and physical characteristics for a high-capacity KEBO 3KVA UPS, designed for server rooms, networking equipment, and mission-critical applications.
1. Power and Performance
| Parameter |
Specification |
Notes |
| VA Rating |
3000VA![]() |
Apparent Power |
| Watt Rating |
2700W![]() |
True Power (Assuming PF=0.9) |
| UPS Topology |
Line-Interactive or Online (Double Conversion) |
Online is typical for high-end 3KVA units. |
| Waveform (Battery Mode) |
Pure Sine Wave |
Essential for sensitive electronic equipment and motors. |
| Transfer Time (Line-Interactive) |
2−6 ms (Typical) |
Time to switch from utility power to battery power. |
| Transfer Time (Online) |
0 ms![]() |
Continuous, seamless power. |
| Efficiency (AC to AC) |
90%−95%![]() |
Higher efficiency in ECO mode if available. |
2. Input Specifications
| Parameter |
Specification |
| Nominal Input Voltage |
220V/230V/240V AC![]() |
| Input Voltage Range |
170−280V AC (Varies by load and model) |
| Nominal Input Frequency |
50Hz/60Hz (Auto-sensing) |
| Input Connection |
IEC-320 C20 or Hardwired Terminal Block |
3. Output Specifications
| Parameter |
Specification |
| Nominal Output Voltage |
220V/230V/240V AC![]() |
| Output Voltage Regulation |
±3% on battery (Line-Interactive) ±1% on battery (Online) |
| Output Sockets |
4−8 IEC C13 sockets, plus 1 IEC C19 (or hardwired output) |
| Overload Capacity |
105%−120% for 30 seconds (typical) |
4. Battery and Runtime
| Parameter |
Specification (Typical) |
| DC Voltage |
72V DC or 96V DC![]() |
| Battery Type |
Sealed Lead-Acid, Maintenance-Free (12V/7Ah to 9Ah each) |
| Typical Runtime (Half Load) |
10−15 minutes![]() |
| Typical Runtime (Full Load) |
3−5 minutes![]() |
| Recharge Time |
4−6 hours to 90% capacity |
| Battery Management |
Automatic self-test, overcharge/deep-discharge protection. |
5. Physical and Environmental
| Parameter |
Specification |
| Form Factor |
Tower / Convertible Rack/Tower |
| Display |
LCD Panel (Shows status, load level, voltage, and battery charge) |
| Dimensions (H×W×D) |
≈400×200×480 mm (Varies widely) |
| Weight |
≈25−35 kg![]() |
| Noise Level |
<50 dBA at 1 meter![]() |
| Operating Temperature |
0∘C−40∘C![]() |
6. Communications and Management
| Feature |
Description |
| Communication Port |
USB Port and RS232 (Serial) |
| Management Software |
Monitoring and shutdown software for Windows/Linux. |
| Alerts |
Audible and visual alarms for low battery, overload, and fault conditions. |
| Surge Protection |
Input surge suppression. |